HYDRIM Surgical Instrument Washer C51W L110W
HYDRIM L110W  Countertop Surgical Instrument Washer
HYDRIM L110W  Undercounter Surgical Instrument Washer
Contact us for pricing that will lower your surgical instrument cleaning costs and deliver the high quality surgical instrument care that you and your surgical instruments deserve.
Surgical Instrument Washer
C51W Countertop Surgical Instrument Washer
Surgical Instrument Washer
L100W Countertop Surgical Instrument Washer
L100W Undercounter Surgical Instrument Washer
washer disinfector cycle instrument rinse temperatures
LX  Surgical Instrument Washer
Compact Surgical Instrument Washers
Countertop Surgical Instrument Washers  
Undercounter Surgical Instrument Washers 
compact Surgical Instrument Washer Disinfectors cuts costs.
Clean full sized Surgical Instrument Trays. ergo Logistics Washers clean surgical instruments safely and effectively with surgical instrument washer racks for cleaning cannulated Surgical Instruments inside and out. Contact us for pricing that will lower your surgical instrument cleaning costs and deliver the high quality surgical instrument care that you and your surgical instruments deserve.
Washer Disinfector Cycle Temperatures
Countertop Surgical Instrument Washer
Countertop Surgical Instrument Washer
Washer Disinfector
Washer Disinfector
washer disinfector instrument washer rinse temperatures
Surgical Instrument Washer Specifications
LX Washer Disinfector  is a heavy-duty, high  volume, single chamber, cabinet style washer designed for thorough and  efficient cleaning of laboratory glassware, utensils, and miscellaneous  items used in research and healthcare facilities.
LYNX 6100LX Surgical Instrument Washer SIZE
  • Compartment usable space:
26” wide x 26" high x 29" deep
  • Overall Unit*”:
42" wide x 80" high x 36" deep Sliding Door(s)
The ideal steris 444 Washer Disinfector replacement
  • improved operating efficiencies
  • larger usable chamber size
  • the LYNX 610 LX  is... Manufactured in the USA 
Surgical Instrument Washer STANDARD FEATURES
Washer Disinfector CONFIGURATION (select one):
  • front load and unload
  • pass through load and unload The The LYNX 610 LX Surgical Instrument Washer is provided with an unload door and an additional cycle status indicator on the unload end, allowing  one-way product flow from the contaminated area to the clean area.
Washer Disinfector shall be provided with a combination of rotating jet spray and direct spindle spraying for all treatment solutions. Washer Disinfector spray system consists of a single rotating spray arm mounted above, and interchangeable spindle wash or a rotating jet spray arms mounted below for internal treatment of the racked items. The bottom header automatically couples to the re-circulated wash/rinse treatment system.

Washer Disinfector VIEWING WINDOW
Washer door(s) shall be provided with a full view, tempered, double  glass viewing window.
washer disinfector instrument washer rinse temperatures
Surgical Instrument Washer Disinfector STAINLESS STEEL TREATMENT COMPONENTS
All treatment components, including jet spray system, screens, pump,  and recirculating piping are constructed of 304 stainless steel.
Surgical Instrument Washer Disinfector PERSONNEL SAFETY FEATURES
Opening the load-end door (or unload-end if pass-through unit),  automatically stops operation of the washer. The door(s) must be  closed, alarm acknowledged, and the “Cycle Start” button depressed to  continue operation.
An Emergency Stop (ES) button is provided on the load-end control panel  (and unload-end if pass-through unit). If the operations of the wash  cycle are interrupted by depressing the (ES) Button, the operator must  reset the button and push the “Cycle Start” button to continue  operations from the beginning of the selected cycle.
Washer Disinfector MULTI CYCLE COLOR/GRAPHIC MICRO COMPUTER CONTROL SYSTEM
A solid-state microcomputer control system monitors and automatically  controls all process operations and functions. A twelve-cycle treatment  menu may be programmed and retained to permit operating personnel to  accommodate a wide variety of loads and processing requirements.  Individual cycle phase times and temperatures and other key process  parameters are programmable. Each cycle may be locked by supervision to  ensure process integrity. The Cycle programming may be controlled by a  supervisory access code. Each cycle program may be reviewed on demand.
washer disinfector instrument washer rinse temperatures
LYNX 6100LX Surgical Instrument Washer AUTOMATIC TREATMENT CYCLE
The standard treatment cycle consists of any or all of the following  phases: Pre-wash, Wash, Rinse, Wash II, Rinse and Final Rinse. All  cycle phases may be selected or deselected by the user. All Wash and  Rinses treatments are re-circulated under pump pressure except the  optional non-re-circulated rinse. The cycle, once activated, is  completely automatic.
Washer Disinfector REMOVABLE DEBRIS SCREENS
Located in the sump, easily removable screens are provided to protect  items and large debris from entering the recirculation system.
LYNX 6100LX Surgical Instrument Washer WATER SAVINGS
Water from the last rinse cycle may be held and utilized as the  pre-wash of the next cycle.
washer disinfector, times and temperatures.
washer disinfector, times and temperatures.
Surgical Instrument Washer ACCESSORIES

Washer Disinfector is provided with a stainless steel trim flange to enclose the opening between one end of the washer and the masonry wall opening. A stainless steel modular wall assembly is designed and manufactured to enclose an open wall area or to create a wall barrier. All materials  and fasteners are of stainless steel construction. A stainless steel transfer cart is provided to connect to the load or  unload end of washer for accessories transportation and ease of loading  of the washer.

Washer Disinfector times and temperatures
washer disinfector instrument washer rinse temperatures
  • color touch screen displays highly visible cycle program data,
  • built with rugged, locally available, nonproprietary, USA Manufactured replacement parts,   
  • washers and washer accessories are interchangeable with steris 444 washer accessories,
  • modem diagnostics for online service diagnostics, evaluations, and software upgrades,
  • green utilities' design for cost cutting utilities consumption,  
  • rinse water can (optionally) be reused for prewash for cost cutting utility savings,
  • space savings standard and custom configurations,
  • the automated washer treatment cycles can be easily reprogrammed by the facility,
  • top-mounted light to illuminate the wash chamber,
Surgical Instrument Washer Disinfector
LX  Surgical Instrument Washers are Manufactured in the USA with reliable nonproprietary replacement parts. LX  Surgical Instrument Washers are the ideal steris 444 Washer Disinfector replacement. The LX  Surgical Instrument Washers offer dramatically improved operating efficiencies. The LX  Surgical Instrument Washers fit into the steris 444 washer footprint size but deliver a larger usable chamber size. The LX  Surgical Instrument Washers and the steris 444 washers have interchangeable accessories. LX  Surgical Instrument Washers are Manufactured in the USA.
LX Surgical Instrument Washer Dimensions
Usable Chamber Size:
  • 26” wide x 26" high x 29" deep
Overall Unit Size:
  • 42" wide x 80" high x 36" deep 
  • improved operating efficiencies
  • larger usable chamber size
  • the LYNX 6100LX  is... Manufactured in the USA 

Washer Disinfector times and temperatures
Surgical Instrument Washer Disinfector
TMED Surgical Instrument Washers deliver Washer Disinfectant Temperature Rinse Cycles
Surgical Instrument Cleaner Surgical Instrument Washers
Surgical Instrument Cleaner Surgical Instrument Washers
Surgical Instrument Cleaner Surgical Instrument Washers
Surgical Instrument Washer Disinfector
Surgical Instrument Cleaner Surgical Instrument Washers
Surgical Instrument Cleaner Surgical Instrument Washers
Surgical Instrument Cleaner Surgical Instrument Washers